How To Bleed Your Radiators

High fuel costs and falling external temperatures can quickly place a drain on household finances, especially when the central heating system is not working efficiently.

Radiators that feel cooler at the top than the bottom and those emitting a banging noise are tell tale signs that you've got air trapped in your system, however it only requires a simple, DIY response to put things right. 



Bleeding radiators, including our cast iron radiator range, involves opening a small valve on the radiator to release air. Here, we walk you through the simple steps to resolve the problem. 

1.     Start by turning off your central heating. 

2.     Locate the bleed valve at the top of the radiator on either the right or left side. This might be brass and hand operated on modern cast iron radiators or need a screwdriver/radiator key on modern steel units. 

3.     Open the bleed valve until water starts to bubble out. Having an old tea towel to cover the open valve will stop dirty water spraying on to your walls or dripping out on to your flooring. This water may be very hot, so be careful to avoid scalding.

4.     With a tea towel ready in one hand, use the other hand to turn the bleed valve about a half turn anticlockwise to open it. When the water starts rushing out, quickly place the tea towel over the hole from where the air is escaping. 

5.     As soon as water starts escaping, close the bleed valve as quickly as possible. 

6.     Topping up the central heating system may be necessary, as bleeding radiators can cause some loss of pressure within the central heating system. 

7.     There should be a pressure gauge for the system near to your boiler. For most domestic hot water heating systems this should read between 1.5 and 2 bar. If the pressure reading is below this level, open the valve that lets water into your central heating system until the gauge returns to the desired pressure level.


8.     Simply turn your heating back on for a warmer more efficient home.

Monday, 18 January 2016

How We Test our Radiators?

A question we often get asked is: “How do Trads test your radiators?” or “How will I know they will be safe in my property?”.

The quick answer would be: we test our radiator quite extensively to ensure that there are no leaks and that they are safe for use. We are also proud to say all our radiator conform to British Standards (BS:EN 442-2) and we have been awarded the ISO:9001 accreditation for Quality Management.



The Ornate Cast Iron Radiator

Testing in more detail

We are confident that our comprehensive period of testing is more than suitable to assess any potential weakness in the casting of each individual section and the connections of complete cast iron radiators.

Once the assembly is complete and the assembly inspection is passed, the radiator/s are carefully transferred to our bespoke water and air testing station.
Here, trained operatives put the radiator through a series rigorous pressure tests. The total time of high pressure testing exceeds more than 24 hours, the pressure that is used is at a rate well beyond that of normal water pressure found in the UK.

High Standards

The reason for such thorough testing is to ensure each and every radiator more than meets the requirements that are expected and exceeds the high level of standards that we impose on ourselves. 
On the rare occasion that a radiator or sections fail, the failed sections are discarded and radiators are re-built with new sections.
Once passed they return to the paint team to complete the ‘Double Painted Method’.

If you’d like to know more, please visit our website or contact one of the team on 0808 1785 533.